Showing posts with label fuel. Show all posts
Showing posts with label fuel. Show all posts

Tuesday, January 24, 2017

CAPCA: Ten Problems Tips and Tricks for Captains

I did a presentation at the Chesapeake Area Professional Captain's Association titled Ten Problems, Tips, and Tricks for Captains. Over sixty people came out on a cold, windy, drizzly January night to spend some time thinking about boating instead of the weather. We had a great time talking about the set of problems I assembled with the assistance of Art Pine and Priscilla Travis of CAPCA. A PDF of the presentation is available at the link below. It is 23MB, but Google Drive seems to do a great job of compressing it for viewing. There is a video in the original presentation and I've included a link to it on the page where it appears. You might get something from the PDF, but I said a lot during the presentation that isn't in the slides.

  -Terry

Ten Problems, Tips, and Tricks for Captains

Sunday, January 18, 2015

Fuel Tank Corrosion - Again

Fuel tank corrosion is a repeat topic on the Yahoo Leopard List. Some people have converted to plastic tanks. Others have stayed with aluminum. There isn't a great answer because both have had problems.

In our post Its Not Over Til Its Over - Port Engine Fuel Tank, we described what we thought was the last of the fuel tank problems. Well, we returned to Annapolis this summer (2014) and found another leak in the port fuel tank. We removed the starboard tank and check it. In both cases, we found salt under the tanks. The port tank had a leak along one of the seams and on the bottom of the sump that's built into the tank. We had cleaned up the water around the port tank before. If we can eliminate the salt water intrusion, we will eliminate the source of corrosion.

It took us two trips to the welder to get the port tank fixed. They had tested it after welding by putting about 6-10 lb of pressure in it and looking for the reading to change. But the weld was leaking. They also couldn't find it by spraying it with diluted dishwashing liquid. However, if it was checked with industrial leak detector, which makes industrial-strength bubbles, the leak was seen. Neither of us was happy about the second trip. We had suspected the original weld because it wasn't shiny all the way around. But they said it was good. We'll know better in the future when we see work that we don't trust and do something to double check it.

Water Stains at Hot Water Bulkhead Feed-Thru
We found a lot of orange staining around the engine cooling water loop that goes to the hot water heater where it comes through the bulkhead. Sure enough, the balsa core was wet when we removed the feed-thru fitting. We cleaned out the rotten balsa, filled with thickened epoxy, and bedded the fitting with butyl tape.























We also added drain holes to the low spots on the shelf that holds the fuel tank and the hot water tank. All holes were sealed with thickened epoxy. We'll be checking periodically to see if salt water is finding its way under the tanks.

Drain Holes Under Hot Water Heater

Drain Holes Under Fuel Tank


























  -Terry

Sunday, January 5, 2014

Is That Holding Tank Full Already?

Monitoring tank usage is important on LUX. We often are traveling in no discharge areas and have to get a holding tank pumpout done before it is full. The float sensors on the holding tanks aren't great. Calcium buildup quickly makes them ineffective. We needed a better way to monitor holding tank capacity and decided that it would also nice to be able to monitor water tank usage, though it is relatively easy to just open the forward lockers and look at the water levels.

There are a number of tank monitoring systems around. Getting one that works for a combination of water, waste, and fuel is rather interesting. It needs to work with potable water, corrosive waste, and flammable liquids. Two systems seem to get the best marks: capacitive sensors or pressure sensors. 

The capacitive sensors work only on non-metalic tanks. Two strips of conductive tape are applied to the side of the tank and the sensing electronics is calibrated to determine the range of values that correspond to the volume of liquid in the tank.

Pressure sensors work by using a dip tube that extends from the top to nearly the bottom of the tank. Either a manual or automatic pump is used to pressurize the tube until bubbles come out the bottom. The pressure is then read as an indication of the amount of liquid that is covering the tube.

Float switch-based systems typically don't work well, particularly in waste systems. Bits of gunk (that's a technical term ;-) ) and calcium buildup will quickly inhibit the float switch operation.

After looking around at some systems, we decided on the Profile Series 8-tank monitoring system from Ferriello Sales (now New Providence Marine Tank Monitor). <http://www.newprovidencemarine.com/> It can monitor up to 8 tanks and can accept input from a variety of sensors, including our existing fuel sensors, a propane tank sensor (for tanks equipped with a sensor), as well as capacitive sensors. The system can handle weird sized tanks, which is a plus on boats. The display can show a summary of all 8 tanks or a higher-resolution display of each tank's capacity. Alarms can be set for full or empty levels. Alarms can be disabled at night, as determined by a photo sensor. Dennis, the owner, has received a number of accolades from people regarding the superior level of service that he provides. Our experience was similar. The system cost, including wire from West Marine, was about $450.

We intend to monitor six tanks: two each of water, waste, and fuel, even though the fuel monitoring is redundant with the fuel gauges at the helm. We don't have propane tanks with sensors, but that's a possibility for the future.

The display is mounted at the top of the navigation station and provides good visibility. The display is in the process of being mounted and is sitting on the counter in front of the open DC electrical panel. The blue tape at the top of the nav station is used to mark the cutout and to protect the gelcoat during the cutting operation. We neglected to get a photo of the completed installation - something to do on the next trip to LUX.

We have reserved space above the Shore Power panel for the genset control panel, which will be installed this summer, 2014. This will put all the AC equipment panels together for ease of monitoring.

The holding tanks were the first to get sensors. The process is easy to follow and works well. We used nearly 100ft of wire to connect both holding tanks and expect to use that amount for the water tanks. The sensors require three connections: Ground, Power, and Sense. The Power and Sense connections have to come from the display. We were able to use the ground wire from the old tank "full" sensors at each tank, so we only needed to run two wires (Red=Power, Blue=Sensor) from the tanks to the display. We used quick-disconnect electrical connectors so that the tanks can be easily removed in the future.

Calibration required emptying the tanks, then filling them, which we did with water at the next pumpout. The system works well, allowing us to monitor all 8 tanks with one glance as well as more detailed views if we're filling water and fuel tanks.

We ran out of wire after doing the holding tank sensors, so we'll add water and fuel monitoring when we return to LUX.

Update 8/5/2021: Yes, we added monitors to the two fresh water tanks and all four have been valuable tools for knowing when to pump out or add water or switch tanks.

-Terry

Wednesday, November 14, 2012

It's Not Over 'Til It's Over - The Port Engine Fuel Tank

I last wrote that the port engine fuel tank problems were all behind us. Well, Murphy was listening and laughed at us. Upon arriving in Marsh Harbor, Abacos Bahamas, Mike and Gee reported a diesel smell in their cabin (port, aft). Mike investigated and found a small, but steady diesel leak under the tank. We unbolted the tank and supported it with blocks to get an idea of what was happening.

Port fuel tank with corrosion on the bottom
The bottom of the tank was encrusted with salt. With a light and a mirror, I was able to see a couple of drips off the bottom of the tank. It was time to empty the tank and remove it. We pumped fuel into the starboard tank using a drill pump, pulling it from the Racor output so that it was like polishing the fuel.

Upon cleaning, we found that the tank had two small holes and several places where there was severe pitting. The tank was deteriorating from the outside. We speculate that the salt came from a water leak from the ports or from when the port engine heat exchanger failed.
Mike took the tank to CJ's in Marsh Harbor, Abaco Bahamas. They did an excellent welding job, spot welding the holes as well as adding new plates across the bottom of the tank. They recognized the tanks immediately, making a comment like "looks like South African tanks."
Port fuel tank after new bottoms are welded
If CJ had not been available to do the welding, we were going to drill and tap the holes and seat a machine screw in each hole, sealed with Permatex Form-a-gasket until we could get to a place where we could have it properly repaired.

We have been told that the starboard tank had a repair done several months prior to our purchase of LUX. One of the things that should be done on survey or phase-out of a Leopard cat is to unbolt and the fuel tanks and check for salt under them. If salt exists there, then require that they be removed and checked. It also makes sense at survey time to check for gunk in the bottom of the tanks and have them cleaned if any gunk is found.

Hopefully, this is the last you'll hear about fuel problems on the port engine.

To read about all our fuel problems and the eventual solution, click on the 'fuel' and 'engine' links in the tag list to the right of the blog.

Here is a useful link about the sources of gunk in diesel from Marsh Marine:
http://www.marshmarine.net/index_8.htm


  -Terry